Environmental compliance is no longer optional. It is a mandatory responsibility.
Through SPARING, industries in Indonesia are required to continuously monitor wastewater quality in real time and transmit data online directly to the Ministry of Environment and Forestry (KLHK).
Lautan Air Indonesia provides reliable, integrated, and regulation-compliant SPARING solutions, supporting industries from system design to long-term operation.
What is SPARING?
SPARING (Sistem Pemantauan Kualitas Air Limbah Secara Terus Menerus dan Dalam Jaringan) is an automated monitoring system that continuously measures wastewater quality parameters and transmits the data online to the KLHK server.
The system aims to:
Ensure compliance with Regulation of the Minister of Environment and Forestry of the Republic of Indonesia No. P.93/MENLKHK/SETJEN/KUM.1/8/2018 and Regulation of the Minister of Environment and Forestry of the Republic of Indonesia No. P.80/MENLKHK/SETJEN/KUM.1/10/2019
Improve transparency in wastewater management
Enable early detection of potential pollution
Support data-driven environmental supervision
Parameters Monitored by SPARING
SPARING continuously monitors key wastewater quality parameters, including:
Parameters: pH, COD, TSS, Flow Rate
- Rayon Industry
- Pulp & Paper Industry
- Upstream Petrochemical Industry
- Palm Oil Industry
Parameters: pH, COD, TSS, NH₃-N, Flow Rate
- Basic Oleochemical Industry
- Textile Industry
- Industrial Estate
Parameters: pH, COD, NH₃-N, Flow Rate
- Petroleum Processing
- Oil & Gas Exploration and Production
Parameters: pH, TSS, Flow Rate
- Gold and Copper Mining
- Coal Mining
- Nickel Mining
Technical Specification of SPARING Equipment
The technical specifications for the SPARING (Sistem Pemantauan Kualitas Air Limbah Secara Terus-Menerus dan Dalam Jaringan) device refer to and must comply with the provisions set forth in:
Lampiran III Halaman 13–14
Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia
Nomor: P.80/MENLHK/SETJEN/KUM.1/10/2019
The technical specifications for the SPARING device must comply with the following provisions:
1. Minimum Measurement Range Requirements
| No. | Parameter | Measurement Range | Unit |
|---|---|---|---|
| 1 | pH | 0 – 14 | Unit |
| 2 | COD | 0 – 50 | mg/L |
| 3 | TSS | 10 – 1,400 | mg/L |
| 4 | NH₃ | 0 – 2,000 | mg/L |
| 5 | Flow Rate* | m³/hour |
* Measurement range is adjusted according to the volume of wastewater discharged.
2. Maximum Measurement Accuracy Requirements
| No. | Parameter | Measurement Accuracy |
|---|---|---|
| 1 | pH | ± 0.1 pH |
| 2 | COD | ± 10% |
| 3 | TSS | ± 10% |
| 4 | NH₃ | ± 10% |
| 5 | Flow Rate* | ± 10% |
SPARING Solutions from Lautan Air Indonesia
Lautan Air Indonesia delivers end-to-end SPARING solutions. We do not only supply equipment but also ensure long-term system performance and data reliability.
1. System Design Based on Wastewater Characteristics
A thorough site assessment ensures the SPARING system is designed according to actual field conditions.
2. High-Quality Instruments and Sensors
We utilize reliable monitoring instruments that are compatible with KLHK reporting requirements.
3. Data Integration with KLHK
Secure and stable configuration of data loggers and communication systems enables real-time data transmission.
4. Professional Installation and Commissioning
Installation and commissioning are performed by experienced technical teams to ensure compliance and system accuracy.
5. Operation, Maintenance, and Calibration
Comprehensive Operation and Maintenance services maintain data accuracy and extend equipment lifespan.